For a shop project in Greece, start with the actual premises and who will look after it between trading periods. Wireless devices can reduce the need for signal cabling to each protection point, but the proposed positions still need suitable mounting, a working radio link and access for service. If the shop closes seasonally, power, reporting and local access need an arrangement that lasts for that closure.
The examples below are representative design situations. A shop in a divided older building and an open retail unit may need different layouts; their city or island location does not establish how many detectors they need.
Make the public area and the hidden rooms visible on the plan
Include the sales area, staff entrance, stockroom, stairs and any basement or mezzanine. Start with the openings and routes an intruder could use. A protected front door does not cover a rear courtyard entrance, and a PIR in the sales area does not establish coverage in a separate stockroom.
If a shop has thick masonry between rooms, compare feasible Hub positions before drilling. Test at each intended detector position using the device’s signal-strength test. Keep a suitable service location in the decision: a central position that cannot be reached without dismantling a display is a poor operational choice.
Where mounting changes require the building owner’s approval, settle those permissions before selecting the final positions. Wireless removes some signal cabling; it does not remove brackets, power needs or building constraints.

Match detection to the shop’s daily use
Consider a representative boutique where customers use the front room and staff occasionally enter a rear stockroom. Decide whether the stockroom is to remain protected during trading. If so, demonstrate the intended device selection and authorised user’s operation on the chosen Hub and software version. A room name in an App alone does not prove the required protection behaviour.
A second representative shop has a shutter that closes after staff leave. Test the detector links with that shutter down, and walk the final departure route. If leaving requires crossing a protected area, configure and demonstrate an appropriate exit arrangement rather than copying a delay from another shop.
Roombanker’s manual describes security scenes, user permissions and detector tests. Use those functions to implement the agreed routine, and verify the result with the person who opens and closes the shop.

Treat seasonal closure as a service decision
Before a long closure, establish which power and internet services will remain active. Battery-powered detectors do not keep the Hub and remote reporting equipment supplied indefinitely. A proposed solar supply needs a compatible, complete power design; a solar-powered siren is not a power source for the whole system.
| Closure condition | Arrangement needed before leaving |
|---|---|
| Owner leaves the area | A named person with access and authority to attend service issues |
| Internet subscription will stop | A supported, tested reporting arrangement that remains available |
| Mains power will stop | A validated supply design for the Hub and all reporting equipment, or a different protection arrangement |
| Premises may be visited by contractors | A controlled access and arming procedure, followed by confirmation that protection is restored |
Do not disable motion detection simply because the shop is vacant. Resolve unwanted movement or environmental exposure while retaining the required intrusion coverage. The detailed seasonal shop planning guide covers closure and reopening as a separate task.

Specify coastal and open-front positions individually
A shop close to the coast may still have protected indoor equipment positions. Equally, a device beside an open frontage may face conditions unlike the interior. Check the actual exposure and the exact product documentation; do not treat indoor devices as outdoor devices or infer marine suitability from an ingress rating.
Keep the Hub indoors in a suitable environment and away from metal objects as directed by its installation guide. Use approved mounting and maintenance instructions. Improvised sealing or greasing is not a substitute for selecting suitable equipment.

Answer the purchase and handover questions
Does the system need shop Wi-Fi? Roombanker field devices use their compatible radio link to the Hub. Remote reporting uses the selected Hub’s supported onward connection. Verify both paths separately; removing Wi-Fi does not establish that remote communication will continue.
Can a Greek monitoring service receive alarms? Compare the exact Hub, connection and receiver requirements with the selected service, then perform an end-to-end test. A protocol name alone is not receiver acceptance.
Which certifications and local services apply? Ask for documentation for the proposed models and the project’s acceptance requirements. Confirm supplier availability, installer support language and service access directly; do not assume them from a country label.
Before handover, have the operator demonstrate opening, closing and the agreed part-protection routine. For a seasonal shop, also name the person who will handle a fault during closure. Refer to the Roombanker user manual for device and user settings, or consult Roombanker Support with the building plan and planned trading calendar.